ElectroCell documents the performance of each installation by taking water samples before the ElectroCell system is started and again after the system has been operating for approximately 30 days. The results of both tests, conducted by an independent third-party laboratory, are then compared and the results reported as the percent of particle reduction.

Metropolitan Museum of Art

New York City
System EC-2000 Particle Precipitator
Highlight 96.5% particle reduction in 12 days
Test Duration 12 Days
PPM Before 3,609 ppm
PPM After 128 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

Nissan North America

Canton, MS
System EC-2000 Particle Precipitator
Highlight 99% Particle Reduction after 6 weeks
Test Duration 6 Weeks
PPM Before 557 ppm
PPM After 6 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

Office of Chief Medical Examiner

Hirsch Center, New York City
System EC-4000 Particle Precipitator
Highlight 98.9% particle reduction in 6 weeks
Test Duration 6 Weeks
PPM Before 617 ppm
PPM After 6 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

OXY - Occidental Permian Irish Station Metering Facility

Anton, TX
System EC-6000 Particle Precipitator
Highlight 99.04% Particle Reduction in 15 days
Test Duration 15 Days
PPM Before 13591 ppm
PPM After 131 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

PSU Hershey Medical Center

Hershey, PA
System EC-6000 Particle Precipitator (Insulated)
Highlight 98% particle reduction in 8 weeks
Test Duration 8 Weeks
PPM Before 4221 ppm
PPM After 83 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

University of Arkansas

Fayetteville, AK
System EC-4000 Particle Precipitator
Highlight 99% particle reduction in 30 days
Test Duration 30 Days
PPM Before 858 ppm
PPM After 9 ppm

All tests completed by independent third-party laboratory. Samples analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.